- The “Signature” tab allows the designer to prevent the AOI from modifications.
- The “Change History” tab displays the history of changes with names and dates and times.
- The “Help” tab will allow the user to create specific help text about the functions and logic used within the AOI.
Let’s create the internal logic used to perform the conversion.
In the logic window for ladder logic development, we have three instructions created for the logic to be used for the conversion.
- The first instruction is a “Compute” instruction allowing us to create the equation for a destinati...
Let’s use the AOI in ladder logic to see the results of the equations used in our AOI.
We will now go to the Instruction toolbar and select the Add-On
tab. We will select the RealPars icon from the toolbar.
The AOI will now be added to rung 0, but it still requires some configuration.
- First, l...
We’ve added a few more instructions to help with the simulation.
If you would like to follow along, the Studio file, named RealParsAOI
can be downloaded from this link: https://bit.ly/38pEFdT
- The TON or Timer On Delay instruction set for 5000 milliseconds or 5 seconds and will increment the C...